| Feature
1: |
|
|
Benefit
1: |
|
The
tie system provides great strength performance at MAXIMUM tie adjustability
(worse case).
Ultimate Tension = 450 lbs;
Ultimate compression = 600 lbs with a
4” cavity plate of applied loading
|
|
Allows
for greater tie spacing and as a result, creates fewer breeches in
the air barrier system.
|
|
|
|
|
|
| Feature
2: |
|
|
Benefit
2: |
|
Assembly
stiffness is greater than 6300 lbs/in in tension and 13,800 lbs/in
in compression.
|
|
The
veneer wall deflection under load will be minimal, which lessens the
likely hood of cracking and the resultant moisture migration through
the crack.
|
|
|
|
|
|
| Feature
3: |
|
|
Benefit
3: |
|
The
veneer tie system is designed for positive single connection to back-up
building structures with mechanical fasteners.
|
|
The
use of a single tek screw with 16 gauge metal stud back up, or the
use of a single Torque-Tie brass masonry fastener for concrete or
masonry back-up; or the use of a single 1/4”
lag for wood stud back up creates fewer penetrations through the air
barrier system. |
|
|
|
|
|
| Feature
4: |
|
|
Benefit
4: |
|
Large
bearing area. The CT-16 Base Plate is 1” X 2” which provides
a solid contact area.
|
|
Large
bearing area. The CT-16 Base Plate is 1” X 2” which provides
a solid contact area.
|
|
|
|
|
|
| Feature
5: |
|
|
Benefit
5: |
|
WT
tie can be used within seismic designated areas or non-seismic areas
without clips, tabs, or add-ons. It is produced from 3/16” diameter
wire manufactured of carbon steel or stainless steel.
|
|
The
WT design simply engages with veneer reinforcement for added ductility
and strength in seismic events. As a basic tie it creates an interlock
with the mortar as a result of its design. Installs quickly and is
safe to handle. |
|
|
|
|
|
| Feature
6: |
|
|
Benefit
6: |
|
Base
plate and tie combination offer significant adjustability.
Vertical adjustability = 1-1/2”
Horizontal movement = +/- 1/2”
|
|
Provides
installation ease and it accommodates for the thermal and seismic
movement of the veneer.
|
|
|
|
|
|
| Feature
7: |
|
|
Benefit
7: |
|
| Tie
cannot disengage. |
|
Complies
with ASCE5/ACI 530/TMS 402 requirements. |
|
|
|
|
|
| Feature
8: |
|
|
Benefit
8: |
|
| Product
features no sharp corners. |
|
Minimizes
personal safety risk. |
|
|
|
|
|
| Feature
9: |
|
|
Benefit
9: |
|
Base
plate assembly is mounted vertically to the stud system.
|
|
Eliminates
mortar build up on the plate which creates a moisture bridge to the
back-up, installs easily and aligns with insulation board. Spray foam
applications do not plug the slot or sag about the plates projection. |
| |
|
|
|
|
| Feature
10: |
|
|
Benefit
10: |
|
| Multi-Functional
Tie |
|
Can
be used with or without veneer reinforcement. |
|
|
|
|
|