Installation

 
The CT-516 is a complete assembly that includes the CT-516 plate and tie plus a mechanical fastener capable of being applied to concrete and/or masonry structures.
Torque Activated: 50 – 100 in – lb • Hex Head Finish – Low Profile • Bolt Head Provides Inspection Source
Low Profile Avoids Insulation or Tie Interference • Zinc Plated or Stainless Bolt with Brass Expanders • Fastener Preload > Four Times Design Load
 
1) Drill 3/8” diameter hole in base material 1-1/2” – 2” deep
2) Blow out drill fines
3) Assemble fastener to the CT-16 Base plate center hole
4) Slip assembly into drilled hole until plate bottoms to base material
5) Tighten fastener, 50 – 100 IN-LB
 
   
 
                           