Product
Series |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
 |
|
 |
|
 |
|
 |
|
 |
|
 |
|
 |
|
 |
|
 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
 |
|
|
|
|
 |
Installation
Procedure and Criteria to Restrain Stone Panel to Solid Back-Up
The Panel-Tie 6000 Series anchors provide an excellent method
of restraining (tension only) a solid façade <3”
thick to various solid or hollow backups. The anchor is installed
by drilling a standard 1/2" masonry hole through the veneer
into the back-up followed by a 1 1/4" diameter countersink
hole in the veneer. Anchor placement is only restricted by edge
and spacing distance. Anchors are installed with a setting tool,
via torque 50-100 in-lb in the back-up. Veneer connections are
tightened 1/4-1/2 turn past hand tight. Custom lengths available
upon request. Counter-boring drill bits available upon requests. |
|
|
 |
|
|
 |
Installation
Procedure and Criteria to Restrain Stone Panel to Solid Back-Up
The Panel-Tie 6000-TGL Series anchors provide an excellent method
of re-anchoring (tension and compression) a solid facade <3"
thick to a solid back-ups. This anchor works especially well
when compression loads are a concern. Anchor is installed by
drilling a 3/4" hole through veneer, 1/2" in back-up
followed by 1 5/8" diameter countersink in the veneer.
Anchor placement is only restricted by edge and spacing distance.
Anchors are installed with a setting tool, via 50-100 in-lb,
and the hex drive head tightened 1/4-1/2 turn past hand tight.
Custom lenghts available upon request. Counter-boring drill
bit available upon request. |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|