Product
Series |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
 |
|
 |
|
 |
|
 |
|
 |
|
 |
|
 |
|
 |
|
 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
 |
|
|
|
|
 |
Installation
Procedure and Criteria to Restrain Stone Panel to Solid Back-Up
The Panel-Tie
6500/6600 Series anchors provide an excellent method of re-anchoring (tension
and bending) a solid façade <3” thick to various solid backups.
Anchor is installed by drilling an appropriate hole through veneer, and
in back-up followed by a 1 1/4” diameter countersink hole in the veneer.
Anchor placement is only restricted by edge and spacing distance. Anchors
are installed with a setting tool, via torque 50-100 in-lb in the back-up.
Veneer connections should be tightened 1/4- 1/2 turns past hand tight. Custom
lengths available upon request. Counter-boring drill bits available upon
request. |
|
|
|
|
|