PART 1
GENERAL |
| |
1.1 |
SECTION
INCLUDES |
|
|
|
|
|
|
|
|
|
A. |
Masonry
repair systems |
|
|
|
|
|
|
|
|
1.2
|
RELATED
SECTIONS |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
A. |
Section 04900 – Masonry Restoration and Cleaning: Coordination
and installation requirements |
|
|
|
|
|
|
|
|
1.3 |
REFERENCES
|
|
|
|
|
|
|
|
|
|
A. |
ACI
530.1/ASCE 6/TMS 602 – Specifications for Masonry Structures |
|
|
|
|
|
|
|
|
|
B. |
American
Society for Testing and Materials (ASTM) A 276 – Standard
Specification for Stainless Steel Bars and Shapes. |
|
|
|
|
|
|
|
|
|
C. |
American
Society for Testing and Materials (ASTM) B 16, Type 360 Brass
- Standard Specification for free Cutting Brass Rod, Bar, and
Shapes for use in Screw Machines. |
|
|
|
|
|
|
|
|
1.4 |
SUBMITTALS |
|
|
|
|
|
|
|
|
|
A. |
Submit under provisions of Section 01300 |
|
|
|
|
|
|
|
|
|
B. |
PANEL
-TIE: Manufacturers data sheets on each product to be used,
including: |
|
|
|
|
|
|
|
|
|
|
|
|
1. |
Preparation
instructions and recommendations |
|
|
|
|
|
|
|
|
|
|
|
|
2. |
Storage
and handling requirements and recommendations. |
|
|
|
|
|
|
|
|
|
|
|
|
3.
|
Installation
methods. |
|
|
|
|
|
|
|
|
1.5 |
DELIVERY,
STORAGE, AND HANDLING |
|
|
|
|
|
|
|
|
|
A. |
Store
products in manufacturer’s unopened packaging until ready
for installation. |
|
|
|
|
|
|
PART 2 PRODUCTS |
|
|
|
|
|
|
|
|
|
|
2.1 |
MANUFACTURER |
|
|
|
|
|
|
|
|
|
A. |
Acceptable Manufacturer:
Construction Tie Products (CTP)
Michigan City, IN, 46360.
Tel: 219-878-1427. Fax: 219-874-3626.
Email: salesctp@comcast.net |
|
|
|
|
|
|
|
|
2.2
|
PRODUCTS |
|
|
|
|
|
|
|
|
|
A. |
Masonry
Repair and Restoration Re-anchoring Existing Stone Panel Veneers
(Selection based on application): |
|
|
|
|
|
|
|
|
|
|
|
|
1.
|
Application:
Wind load restraint for one direction loading to Solid
Back-up. |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
a. |
6000
Series Panel-Tie Anchor with EPDM washer. |
|
|
|
|
|
|
|
|
|
|
|
|
2.
|
Application:
Wind load restraint for dual directional loading to Solid Back-up. |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
a. |
6000-TGL
Series Panel-Tie Anchor with EPDM washer. |
|
|
|
|
|
|
|
|
|
|
|
|
3.
|
Application:
Wind load restraint for one direction loading to Hollow
Back-up. |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
a.
|
6100
Series Panel-Tie Anchor with EPDM washer |
|
|
|
|
|
|
|
|
|
|
|
|
4. |
Application:
Wind load restraint for dual directional loading to
Hollow Back-up. |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
a. |
6100-TGL
Series Panel-Tie Anchor with EPDM washer |
|
|
|
|
|
|
|
|
|
|
|
|
5.
|
Application:
Wind load restraint for one direction to Structural Steel Back-up |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
a. |
6100-S
Series Panel-Tie Anchor with EPDM washer. |
|
|
|
|
|
|
|
|
|
|
|
|
6. |
Application:
Wind load restraint for dual directional loading to
Structural Steel Back-up |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
a. |
6100-S-TGL
Series Panel-Tie Anchor with EPDM washer |
|
|
|
|
|
|
|
|
|
|
|
|
7.
|
Application:
Wind Load Restraint and Panel support to Solid Back-up using
torque activation |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
a. |
6500
Series Panel-Tie Anchor – ½” Diameter with
EPDM washer or, |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
b. |
6600
Series Panel-Tie Anchor – 3/8” Diameter with EPDM
washer |
|
|
|
|
|
|
|
|
|
|
|
|
8. |
Application:
Wind Load Restraint and Panel support to Concrete
or Grouted Masonry Back-up using Hammer set activation. |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
a.
|
HS
Series Panel-Tie Anchor, (size) Diameter with EPDM
washer. |
|
|
|
|
|
|
|
|
|
|
|
|
9.
|
Application:
Wind load restraint for one direction loading to
Stud (Metal, or Wood) Back-up. |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
a. |
6300
Series Panel-Tie Anchor with EDPM washer |
|
|
|
|
|
|
|
|
|
|
|
|
10. |
Application:
Wind load restraint for dual Directional loading to
Stud (Metal, or Wood) Back-up. |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
a. |
6300-TGL
Series Panel-Tie Anchor with EDPM washer |
|
|
|
|
|
|
PART
3 EXECUTION |
|
|
|
|
|
|
|
|
|
|
3.1 |
PREPARATION |
|
|
|
|
|
|
|
|
|
A. |
Locate
anchors in the area to be anchored per project drawings and
details. |
|
|
|
|
|
|
|
|
3.2 |
INSTALLATION |
|
|
|
|
|
|
|
|
|
A. |
Select proper anchor length by field verification. |
|
|
|
|
|
|
|
|
|
B. |
Drill
proper hole size per the anchor type and blow out drill fines. |
|
|
|
|
|
|
|
|
|
C.
|
Using appropriate setting tool and adaptors, tighten back-up
anchor to recommended torque range, then tighten toggle to rear
of stone panel (if appropriate), then tighten stone panel portion
½ - ¾ turns past snug. |
|
|
|
|
|
|
|
|
|
D.
|
Conceal
anchor with specified grout, stone plug or caulk. |
|
|
|
|
|